High Quality for Total Station Ruide R2 - Optics Instruments GTS1002 Topcan Total Station – Haodi
High Quality for Total Station Ruide R2 - Optics Instruments GTS1002 Topcan Total Station – Haodi Detail:
HOW TO READ THIS MANUAL
Thank you for selecting the GTS-1002
• Please read this Operator’s manual carefully, before using this product.
• GTS has a function to output data to a connected host computer. Command operations from a host computer can also be performed. For details, refer to “Communication manual” and ask your local dealer.
• The specifications and general appearance of the instrument are subject to change without prior notice and without obligation by TOPCON CORPORATION and may differ from those appearing in this manual.
• The content of this manual is subject to change without notice.
• Some of the diagrams shown in this manual may be simplified for easier understanding.
• Always keep this manual in a convenient location and read it when necessary.
• This manual is protected by copyright and all rights are reserved by TOPCON CORPORATION.
• Except as permitted by Copyright law, this manual may not be copied, and no part of this manual may be reproduced in any form or by any means.
• This manual may not be modified, adapted or otherwise used for the production of derivative works.
Symbols
The following conventions are used in this manual.
e : Indicates precautions and important items which should be read before operations.
a : Indicates the chapter title to refer to for additional information.
B : Indicates supplementary explanation.
Notes regarding manual style
• Except where stated, “GTS” means /GTS1002.
• Screens and illustrations appearing in this manual are of GTS-1002.
• Learn basic key operations in “BASIC OPERATION” before you read each measurement procedure.
• For selecting options and inputting figures, see “Basic Key Operation” .
• Measurement procedures are based on continuous measurement. Some information about procedures
when other measurement options are selected can be found in “Note” (B).
• Bluetooth® is a registered trademark of Bluetooth SIG, Inc.
• KODAK is a registered trademark of Eastman Kodak Company.
• All other company and product names featured in this manual are trademarks or registered trademarks of each respective organization.
Specification
Model | GTS-1002 |
Telescope | |
Magnification/Resolving power | 30X/2.5″ |
Other | Length: 150mm, Objective aperture: 45mm (EDM:48mm), |
Image: Erect, Field of view: 1°30′ (26m/1,000m), | |
Minimum focus: 1.3m | |
Angle measurement | |
Display resolutions | 1″/5″ |
Accuracy (ISO 17123-3:2001) | 2” |
Method | Absolute |
Compensator | Dual-axis liquid tilt sensor, working range: ±6′ |
Distance measurement | |
Laser output level | Non prism: 3R Prism/ Reflector 1 |
Measuring range | |
(under average conditions *1 ) | |
Reflectorless | 0.3 ~ 350m |
Reflector | RS90N-K:1.3 ~ 500m |
RS50N-K:1.3 ~ 300m | |
RS10N-K:1.3 ~ 100m | |
Mini prism | 1.3 ~ 500m |
One prism | 1.3 ~ 4,000m/ under average conditions *1 : 1.3 ~ 5,000m |
Accuracy | |
Reflectorless | (3+2ppm×D)mm |
Reflector | (3+2ppm×D)mm |
Prism | (2+2ppm×D)mm |
Measurement time | Fine: 1mm: 0.9s Coarse: 0.7s, Tracking: 0.3s |
Interface and Data management | |
Display/keyboard | Adjustable contrast, backlit LCD graphic display / |
With backlit 25 key (alphanumeric keyboard) | |
Control panel location | On both faces |
Data storage | |
Internal memory | 10,000pts. |
External memory | USB flash drives (maximum 8GB) |
Interface | RS-232C; USB2.0 |
General | |
laser Designator | Coaxial red laser |
Levels | |
Circular level | ±6′ |
Plate level | 10′ /2mm |
Optical plummet telescope | Magnification: 3x, Focusing range: 0.3m to infinity, |
Dust and water protection | IP66 |
Operating temperature | “-20 ~ +60℃ |
Size | 191mm(W)×181mm(L)×348mm(H) |
Weight | 5.6kg |
Power supply | |
Battery | BT-L2 lithium battery |
Working time | 25 hours |
Product detail pictures:
Related Product Guide:
We strive for excellence, service the customers", hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for High Quality for Total Station Ruide R2 - Optics Instruments GTS1002 Topcan Total Station – Haodi , The product will supply to all over the world, such as: Comoros, Korea, Lisbon, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We are able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and products. For anyone who is interested in our company and items, please make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are going to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please really feel no cost to speak to us for enterprise. nd we believe we are going to share the most effective trading practical experience with all our merchants.